Artigo em revista científica Q1
A flexible, low-cost and algorithm-independent calibrator for automated blood pressure measuring devices
José Miguel Costa Dias Pereira (Pereira, J. M. C. D.); Gonçalo Ribeiro (Ribeiro, G.); Octavian Postolache (Postolache, O.);
Título Revista
Applied Sciences
Ano (publicação definitiva)
2025
Língua
Inglês
País
Suíça
Mais Informação
Web of Science®

N.º de citações: 0

(Última verificação: 2025-12-14 16:50)

Ver o registo na Web of Science®

Scopus

N.º de citações: 0

(Última verificação: 2025-12-09 03:24)

Ver o registo na Scopus

Google Scholar

N.º de citações: 0

(Última verificação: 2025-12-12 06:20)

Ver o registo no Google Scholar

Esta publicação não está indexada no Overton

Abstract/Resumo
Arterial hypertension is one of the most important public health problems, especially in developed countries. The quality and calibration of blood pressure (BP) equipment used for non-invasive blood pressure (NIBP) measurement are essential to obtain accurate data that support correct medical diagnostics. This paper includes the hardware and software description of a flexible, low-cost and algorithm-independent calibrator prototype that can be used for the static and dynamic calibration of automated blood pressure measuring devices (ABPMDs). In the context of this paper, the meaning of calibrator flexibility is mainly related to its ability to adapt or change easily in response to different situations in terms of the calibration of ABPMDs that can use a variety of calibration settings without the need to use specific oscillometric curves from different ABPMD manufacturers. The hardware part of the calibrator includes mainly an electro-pneumatic regulator, used to generate dynamic pressure signals with arbitrary waveforms, amplitudes and frequencies, a pressure sensor, remotely connected through a pneumatic tube to the blood pressure (BP) cuff, a blood pressure release valve and analog conditioning circuits, plus the A/D converter. The software part of the calibrator, mainly developed in LabVIEW 20, enables the simulation of oscillometric pressure pulses with different envelope profiles and the implementation of the main algorithms that are typically used to evaluate systolic, diastolic and mean arterial pressure values. Simulation and experimental results that were obtained validate the theoretical expectations and show a very acceptable level of accuracy and performance of the presented NIBP calibrator prototype. The prototype calibration results were also validated using a certified NIBP calibrator that is frequently used in clinical environments.
Agradecimentos/Acknowledgements
This work is funded by FCT/MECI through national funds and co-funded EU funds under UID/50008: Instituto de Telecomunicações.
Palavras-chave
Automated blood pressure measuring devices (BPMDs),Oscillometric method,Electro-pneumatic pressure regulator,Calibration,Health primary care
  • Ciências da Computação e da Informação - Ciências Naturais
  • Ciências Físicas - Ciências Naturais
  • Ciências Químicas - Ciências Naturais
  • Outras Ciências Naturais - Ciências Naturais
  • Engenharia Civil - Engenharia e Tecnologia
  • Outras Engenharias e Tecnologias - Engenharia e Tecnologia
  • Engenharia Química - Engenharia e Tecnologia
  • Engenharia dos Materiais - Engenharia e Tecnologia
Registos de financiamentos
Referência de financiamento Entidade Financiadora
UID/50008 Fundação para a Ciência e a Tecnologia