Scientific journal paper Q2
Does subjective assessment of dialyzer appearance reflect dialyzer performance in online hemodiafiltration?
João Fazendeiro Matos (Matos, J. F.); Bruno Pinto (Pinto, B.); Carla Félix (Félix, C.); Helena Carvalho (Carvalho, H.); Pedro Ponce (Ponce, P.); Ricardo Peralta (Peralta, R.);
Journal Title
Hemodialysis International
Year (definitive publication)
2020
Language
English
Country
United States of America
More Information
Web of Science®

Times Cited: 7

(Last checked: 2024-12-19 05:31)

View record in Web of Science®


: 1.2
Scopus

Times Cited: 9

(Last checked: 2024-12-15 21:35)

View record in Scopus


: 1.6
Google Scholar

This publication is not indexed in Google Scholar

Abstract
Introduction:In post-dilution online hemodiafiltration, a very thin balance subsists in preventingcoagulation of the extracorporeal circuit (ECC) during treatment and bleeding in the patient, con-cerning dialyzer status and anticoagulation dose.The aim of this study was to assess whether there are clinical outcome differences between thevisual aspect of the dialyzer’s status in terms of clottedfibers at end of dialysis treatments, single-pool urea kinetic modeling (spKt/V) and substitution volume (SubsVol).Methods:It is a multicenter, descriptive-correlational study, involving 2829 patients during April2016. Previous training was given to the Nursing staff to evaluate and classify both the dialyzer’sand the venous chamber’s appearance of the ECC venous line. Registration was performed at bed-side immediately after the patient disconnection.Findings and discussion:Mean age was 68.96 years (SD= 13.75), 60.8% were men. The averagehematocrit was 33.91% (SD= 3.45%). The average dry weight was 68.53 kg (SD= 13.27 kg). Meanunfractioned heparin (UFH) dose was 58.13 IU/kg. Only 32.4% of the patients had a clean dialyzerat the end of treatment. 19.4% of patientsfinished the treatment with more than 10% of clottedfibers. Patients with no residual blood (clean, 32.4%) presented a higher UFH dose (66.32 IU/kg)compared to overall average dose. UFH dose had a significant effect on dialyzer status. There weresignificant differences in average ofspKt/V and SubsVol between the category clean and the othercategories of dialyzer’s status.Evaluating the dialyzer status represents an excellent opportunity to help the physicians to estab-lish an ideal heparin dose. Only the categorycleanis significant to achieve the target. The nursingstaff, by classifying the ECC appearance at patient’s bedside and recording it in a centralized database, can be a major contributor to achieve an individualized and optimal UFH dose and subsequently better patient outcomes.
Acknowledgements
--
Keywords
Anticoagulation,Hemodiafiltration,Heparin,Extracorporeal circuits,Dialysis adequacy
  • Health Sciences - Medical and Health Sciences
Funding Records
Funding Reference Funding Entity
UID/SOC/03126/2013 Fundação para a Ciência e a Tecnologia

With the objective to increase the research activity directed towards the achievement of the United Nations 2030 Sustainable Development Goals, the possibility of associating scientific publications with the Sustainable Development Goals is now available in Ciência-IUL. These are the Sustainable Development Goals identified by the author(s) for this publication. For more detailed information on the Sustainable Development Goals, click here.