Scientific journal paper Q2
Sparse-coding denoising applied to reversible conformational switching of a porphyrin self?assembled monolayer induced by scanning tunnelling microscopy
João Pedro Oliveira (Oliveira, J.); A.M. BRAGANÇA (A.M. BRAGANÇA); Luís Alcácer (Alcácer, L.); Jorge Morgado (Morgado, J.); M. A. T. Figueiredo (M. A. T. Figueiredo); José Bioucas-Dias (Bioucas-Dias, J.M.); Quirina Ferreira (Quirina Ferreira); et al.
Journal Title
Journal of Microscopy
Year (definitive publication)
2018
Language
English
Country
United Kingdom
More Information
Web of Science®

Times Cited: 4

(Last checked: 2024-11-20 16:59)

View record in Web of Science®


: 0.4
Scopus

Times Cited: 4

(Last checked: 2024-11-21 13:55)

View record in Scopus


: 0.4
Google Scholar

Times Cited: 5

(Last checked: 2024-11-17 19:00)

View record in Google Scholar

Abstract
Scanning tunnelling microscopy (STM) was used to induce conformational molecular switching on a self-assembled monolayer of zinc-octaethylporphyrin on a graphite/tetradecane interface at room temperature. A reversible conformational change controlled by applying a tip voltage was observed. Consecutive STM images acquired at alternating tip voltages showed that at 0.4 V the porphyrin monolayer presents a molecular arrangement formed by alternate rows with two different types of structural conformations and when the potential is increased to 0.7 V the monolayer presents only one type of conformation. In this paper, we characterize these porphyrin conformational dynamics by analyzing the STM images, which were improved for better quality and interpretation by means of a denoising algorithm, adapted to process STM images from state of the art image processing and analysis methods. STM remains the best technique to 'see' and to manipulate the matter at atomic scale. A very sharp tip a few angstroms of the surface can provide images of molecules and atoms with a powerful resolution. However, these images are strongly affected by noise which is necessary to correct and eliminate. This paper is about new computational tools specifically developed to denoise the images acquired with STM. The new algorithms were tested in STM images, obtained at room temperature, of porphyrin monolayer which presents reversible conformational change in function of the tip bias voltage. Images with high resolution, acquired in real time, show that the porphyrins have different molecular arrangements whether the tip voltage is 0.4 V or 0.7 V. Journal compilation © 2018 Royal Microscopical Society.
Acknowledgements
--
Keywords
Graphite,Image analysis,Molecular switches,Scanning tunneling microscopy
  • Other Engineering and Technology Sciences - Engineering and Technology
Funding Records
Funding Reference Funding Entity
SFRH/BPD/75338/2010 Fundação para a Ciência e a Tecnologia
UID/EEA/50008/2013 Fundação para a Ciência e a Tecnologia
Related Projects

This publication is an output of the following project(s):

With the objective to increase the research activity directed towards the achievement of the United Nations 2030 Sustainable Development Goals, the possibility of associating scientific publications with the Sustainable Development Goals is now available in Ciência-IUL. These are the Sustainable Development Goals identified by the author(s) for this publication. For more detailed information on the Sustainable Development Goals, click here.