Matteo Savazzi (Savazzi, M.); Soroush Abedi (Abedi, S.); Niko Ištuk (Ištuk, N.); Nadine Joachimowicz (Joachimowicz, N.); Hélène Roussel (Roussel, H.); Emily Porter (Porter, E.); Martin O’Halloran (O’Halloran, M.); Jorge Rodrigues da Costa (Costa, J. R.); Carlos António Cardoso Fernandes (Fernandes, C. A.); João Felício (Felício, J. M.); Raquel Conceição (Conceição, R. C.); et al.
Título Revista
Sensors
Ano (publicação definitiva)
2020
Língua
Inglês
País
Suíça
Mais Informação
Web of Science®

N.º de citações: 6

(Última verificação: 2024-12-19 07:25)

Ver o registo na Web of Science®


: 0.5
Scopus

N.º de citações: 9

(Última verificação: 2024-12-16 12:59)

Ver o registo na Scopus


: 0.5
Google Scholar

N.º de citações: 14

(Última verificação: 2024-12-17 05:56)

Ver o registo no Google Scholar

Abstract/Resumo
We produced an anatomically and dielectrically realistic phantom of the axillary region to enable the experimental assessment of Axillary Lymph Node (ALN) imaging using microwave imaging technology. We segmented a thoracic Computed Tomography (CT) scan and created a computer-aided designed file containing the anatomical configuration of the axillary region. The phantom comprises five 3D-printed parts representing the main tissues of interest of the axillary region for the purpose of microwave imaging: fat, muscle, bone, ALNs, and lung. The phantom allows the experimental assessment of multiple anatomical configurations, by including ALNs of different size, shape, and number in several locations. Except for the bone mimicking organ, which is made of solid conductive polymer, we 3D-printed cavities to represent the fat, muscle, ALN, and lung and filled them with appropriate tissue-mimicking liquids. Existing studies about complex permittivity of ALNs have reported limitations. To address these, we measured the complex permittivity of both human and animal lymph nodes using the standard open-ended coaxial-probe technique, over the 0.5 GHz–8.5 GHz frequency band, thus extending current knowledge on dielectric properties of ALNs. Lastly, we numerically evaluated the effect of the polymer which constitutes the cavities of the phantom and compared it to the realistic axillary region. The results showed a maximum difference of 7 dB at 4 GHz in the electric field magnitude coupled to the tissues and a maximum of 10 dB difference in the ALN response. Our results showed that the phantom is a good representation of the axillary region and a viable tool for pre-clinical assessment of microwave imaging technology.
Agradecimentos/Acknowledgements
--
Palavras-chave
Anthropomorphic phantom,Axillary lymph node diagnosis,Biological tissue dielectric properties,Breast cancer,Microwave imaging,Open-ended coaxial-probe,Pre-clinical testing
  • Engenharia Eletrotécnica, Eletrónica e Informática - Engenharia e Tecnologia
Registos de financiamentos
Referência de financiamento Entidade Financiadora
764479 Comissão Europeia
UIDB/00645/2020 Fundação para a Ciência e a Tecnologia
UIDB/EEA/50008/2020 Fundação para a Ciência e a Tecnologia

Com o objetivo de aumentar a investigação direcionada para o cumprimento dos Objetivos do Desenvolvimento Sustentável para 2030 das Nações Unidas, é disponibilizada no Ciência-IUL a possibilidade de associação, quando aplicável, dos artigos científicos aos Objetivos do Desenvolvimento Sustentável. Estes são os Objetivos do Desenvolvimento Sustentável identificados pelo(s) autor(es) para esta publicação. Para uma informação detalhada dos Objetivos do Desenvolvimento Sustentável, clique aqui.