Scientific journal paper Q1
Development of an anthropomorphic phantom of the axillary region for microwave imaging assessment
Matteo Savazzi (Savazzi, M.); Soroush Abedi (Abedi, S.); Niko Ištuk (Ištuk, N.); Nadine Joachimowicz (Joachimowicz, N.); Hélène Roussel (Roussel, H.); Emily Porter (Porter, E.); Martin O’Halloran (O’Halloran, M.); Jorge Rodrigues da Costa (Costa, J. R.); Carlos António Cardoso Fernandes (Fernandes, C. A.); João Felício (Felício, J. M.); Raquel Conceição (Conceição, R. C.); et al.
Journal Title
Sensors
Year (definitive publication)
2020
Language
English
Country
Switzerland
More Information
Web of Science®

Times Cited: 6

(Last checked: 2024-12-19 07:25)

View record in Web of Science®


: 0.5
Scopus

Times Cited: 9

(Last checked: 2024-12-16 12:59)

View record in Scopus


: 0.5
Google Scholar

Times Cited: 14

(Last checked: 2024-12-17 05:56)

View record in Google Scholar

Abstract
We produced an anatomically and dielectrically realistic phantom of the axillary region to enable the experimental assessment of Axillary Lymph Node (ALN) imaging using microwave imaging technology. We segmented a thoracic Computed Tomography (CT) scan and created a computer-aided designed file containing the anatomical configuration of the axillary region. The phantom comprises five 3D-printed parts representing the main tissues of interest of the axillary region for the purpose of microwave imaging: fat, muscle, bone, ALNs, and lung. The phantom allows the experimental assessment of multiple anatomical configurations, by including ALNs of different size, shape, and number in several locations. Except for the bone mimicking organ, which is made of solid conductive polymer, we 3D-printed cavities to represent the fat, muscle, ALN, and lung and filled them with appropriate tissue-mimicking liquids. Existing studies about complex permittivity of ALNs have reported limitations. To address these, we measured the complex permittivity of both human and animal lymph nodes using the standard open-ended coaxial-probe technique, over the 0.5 GHz–8.5 GHz frequency band, thus extending current knowledge on dielectric properties of ALNs. Lastly, we numerically evaluated the effect of the polymer which constitutes the cavities of the phantom and compared it to the realistic axillary region. The results showed a maximum difference of 7 dB at 4 GHz in the electric field magnitude coupled to the tissues and a maximum of 10 dB difference in the ALN response. Our results showed that the phantom is a good representation of the axillary region and a viable tool for pre-clinical assessment of microwave imaging technology.
Acknowledgements
--
Keywords
Anthropomorphic phantom,Axillary lymph node diagnosis,Biological tissue dielectric properties,Breast cancer,Microwave imaging,Open-ended coaxial-probe,Pre-clinical testing
  • Electrical Engineering, Electronic Engineering, Information Engineering - Engineering and Technology
Funding Records
Funding Reference Funding Entity
764479 Comissão Europeia
UIDB/00645/2020 Fundação para a Ciência e a Tecnologia
UIDB/EEA/50008/2020 Fundação para a Ciência e a Tecnologia

With the objective to increase the research activity directed towards the achievement of the United Nations 2030 Sustainable Development Goals, the possibility of associating scientific publications with the Sustainable Development Goals is now available in Ciência-IUL. These are the Sustainable Development Goals identified by the author(s) for this publication. For more detailed information on the Sustainable Development Goals, click here.